110kV Voltage Transformer Inductive Outdoor Electric Substation Equipment

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2024-05-20 22:07

  • Browse the number:

    4

Send an inquiries

Company Profile

Dalian Huayi Electric Power Electric Appliances Co., Ltd

By certification [File Integrity]

Contact: oloboror(Mr.)  

Email:

Telephone:

Phone:

Area: Beijing

address: No.66 Mogufang Village, Changdianpu Community, Economic Development Zone, Pulandian, Dalian. Liaoning Province,China

Website: http://hkiachfn.yonghao2011.com/

Product details
110kV Voltage Transformer Inductive Outdoor Electric Substation Equipment
110kVvoltage transformer/ potential transformer is used in power stations for metering and protection purpose under service ambient temperature of -55?~+50?. Insulation altitude is less than 2000m or according to user’s request.

Here we have two options for your selection, cascade and monopole structure

Both types we have more than 10 years experience, and all of them have type test reports from independent lab, also we have detailed and strict factory in line and final routine test, we are a traditional manufacturer of instrument transformer, we have a complete production line, most parts are produced by ourselves, so we have price and quality advantages, we are original source, it can be inspected from starting and internal.
Our products have been exported to Canada, Pakistan, Armenia,l Albania and so on.
Presently we never met any complain from clients, Most of them are with a well operation mode.

Product Name 110kV VT Voltage Transformer Inductive Outdoor Electric Substation Equipment
Brand Name HYEE
Origin China
Phase Single
Coil Structure Wound
Type Cascade / Monopole
Color Brown/White
Frequency 50/60Hz
Certification ASTA/CTQC/IEC/SGS/ISO9001
Package Wooden Carton
Delivery Time: 30 days



Rated primary voltage, kV
Highest voltage for equipment, kV
Rated frequency, Hz 50;60
Rated power frequency withstand voltage, kV 140/160 230 275 460
Rated lightning impulse voltage, kV 325/350 550 650 1050
2000
Flashover distance, mm 780 1050 1300
Cree. distance, mm W1:1450
W2:1820
W3:2250 W1:2520
W2:3150
W3:3910 W1:2900
W2:3630
W3:4500 W1:5040
W2:6300
W3:7820
Mechanical load, N 1250 1250 1250 1250
Rated secondary voltage, kV
Secondary terminal marks 1a-1n 2a-2n da-dn
Accuracy class 0.2 0.5 3P
Rated output, VA 100 250 300
150 150 300
150 - 300
Thermal limiting output, VA 2000
Rated voltage factor 1.2continuous; 1.9/8h (66kV)
1.2continuous; 1.5/30s(110~220kV)
link:http://www.hyee-current-transformer.com